Home
/ Ohio / Heavy Duty DC Power Supplies
Heavy-Duty
DC
Power Supplies
Lifting
Magnet and Industrial-Strength Power Supplies
Ohio
Magnetics’ DC Power Supplies for lifting magnets are available in both
a fixed voltage output and a variable voltage output. Fixed Voltage
output DC power supplies (usually 230 VDC or 115 VDC) are used in most
general magnet applications. Variable Voltage supplies (usually 0-230
VDC or 0-300 VDC) are used in applications of fanning, boost/carry, flux
reduction, constant flux regulation and similar applications.
Voltage
outputs can be set via potentiometers for voltage limit-current
regulation or current-limit regulation.
Because
the cold current of the magnet is 30%-50% greater than the operating
current, the power supply must be sized for the cold rating of the
magnet at 25°C.
(Note:
Ohio also offers Low Voltage DC Power Supplies for
smaller magnets.)
 
Features
-
NEMA 12 (IP-65)
enclosure natural convection
-
North
American or international input voltages; 3-phase; 50 or 60 Hz
-
480
V or 240 VAC input voltage; 3-phase; 60 Hz
-
Magnetic
line starter with 3-phase overload relay protection
-
Adjustable
taps on power transformers to match input line conditions
-
Fast-acting
fuse protection for diode bridge
-
Transient
surge protection
-
DC
output fuses for short circuit protection
-
AC
"power on" indicator light (neon)
-
Wall-mounted
enclosures to 10 KW; floor-mounted enclosures above 10 KW
-
110
/ 120 V (North America) or 220 / 240 V (international) control
voltage for input switching and operation of accessories
-
120
VAC control for input power switching
-
Input
and output power terminal blocks
-
120
V or 115 VDC output voltage (115 VDC output only to 25 kW)
-
Modular
diodes / SCRs for easy replacement
-
Convection-
cooled up to 6.5 kW (230 V) or 4 kW (115 V); fan-cooled above 6.5 kW
(230 V) or 4 kW (115 V)
-
Separate
230 V supply for controllers on all variable voltage supplies
Magnet
DC Power Supply Specifications
|
Full Load Efficiency
|
90%-96%
|
|
Power Factor
|
92%-95%
|
|
Voltage Regulation
|
6% or Less
|
|
Full Wave Output Ripple
|
4.6%
|
|
Power Ratings
|
100% continuous
|
|
@ 60°C
Ambient
|
125%, 2 hours
|
Top
For
pricing information, please supply:
-
Input
Voltage and Frequency
-
Input
Line Equipment Desired (see options)
-
DC
Output Voltage
-
Magnet
Cold Current Rating at 25°C
-
Enclosure
IEC 529 Style or NEMA 12 (IP-55) Standard
-
Additional
Options
-
Quantity
(Note:
Service, parts replacement and re-building are available on existing
equipment. Call for cost-saving details!)
Top
DC
Power Supply Data for Fixed and Variable DC Power Supplies
|
KW1
|
Amps
@ 230 V
|
Amps
@ 115 V
|
Enclosure
Size
H*
x W x D
(in
/ mm)
|
Weight
/ Mass
(lb
/ kg)
|
|
2
|
8.7
|
16.6
|
36
x 30 x 12
915
x 760 x 305
|
238
110
|
|
4
|
17.2
|
33.3
|
36
x 30 x 12
915
x 760 x 305
|
265
120
|
|
6.5
|
28.0
|
54.2
|
36
x 30 x 12
915
x 760 x 305
|
310
140
|
|
10
|
43.1
|
83.3
|
36
x 30 x 12
915
x 760 x 305
|
355
160
|
|
15
|
64.7
|
125.0
|
48
x 36 x 16
1220
x 915 x 405
|
545
250
|
|
20
|
86.2
|
166.6
|
48
x 36 x 16
1220
x 915 x 405
|
595
270
|
|
25
|
109.0
|
208.0
|
48
x 36 x 16
1220
x 915 x 405
|
640
290
|
|
35
|
151.0
|
|
60
x 36 x 20
1525
x 915 x 510
|
800
360
|
|
45
|
194.0
|
|
60
x 36 x 20
1525
x 915 x 510
|
875
400
|
|
55
|
237.0
|
|
60
x 36 x 20
1525
x 915 x 510
|
950
430
|
|
65
|
283.0
|
|
60
x 48 x 24
1525
x 1220 x 610
|
1060
480
|
|
75
|
326.0
|
|
60
x 48 x 24
1525
x 1220 x 610
|
1100
500
|
|
87.5
|
380.0
|
|
60
x 48 x 24
1525
x 1220 x 610
|
1145
520
|
|
100
|
435.0
|
|
60
x 48 x 24
1525
x 1220 x 610
|
1255
570
|
*:
Add 12 in. (305 mm) to height for leg kit on floor-mounted models.
1:
On 0-280 V variable voltage output models, power output in kW is based
on power delivered to load when voltage is set to 230 VDC.
Top
 
Optional
Features
-
IP32,
IP66 enclosures natural* convection
-
Latch
lock on enclosures (where possible)
-
3-wire
pushbutton “on/off” control or 2-wire selector switch type
“on/off” control, both available as local or remote package
-
Circuit
breaker disconnect (local or remote)
-
Variable
voltage:
-
0-230 V system for flux reduction, fanning,
current/voltage regulation applications
-
0-300 V systems for boost/carry,
current/voltage regulation applications
-
Power
relay for operation of controller lift/drop coil from 110/220 V (North
America) or 220/240 V (international) via pendant control
-
Special
requests available – please contact the factory
(*):
NEMA
3R = IP32
NEMA 12
= IP65
NEMA
4 = IP66
NEMA
4X = IP66
Top
To
get a customized solution for your specific application, contact the
factory, or talk with the Ohio rep / dealer
nearest you.
|