CWX
The
CWX and DCWX series of copper wound lifting magnets provide maximum lift
in severe-duty, tough scrap handling applications. These copper wound
magnets feature either standard field or deep field designs to meet the
ever-growing demands for cost-effective, productive, long-lived
solutions.
Typical
Applications

Lifting
Magnet Design Form (Excel form)
Features
-
Copper wound severe-duty magnets for
the toughest scrap handling applications
-
Added lifting capacity from copper
wound field
-
Optional deep field design (DCWX),
to provide an even more powerful gripping force
-
230 VDC standard; special voltages
available by request
|
Average
Lifting Capacity in Lbs.
(based on specifications from Institute of Scrap
Iron & Steel) |
|
Size
(dia.) |
Single
Slab
or
Billet |
Machine
Cast
Pig
Iron |
#1
Heavy
Melt |
#1
Machine
Scrap |
#2
Broken |
Steel
Turnings |
|
34"
CWX |
Inquire |
750
|
750
|
Inquire |
300 -
500
|
275
|
|
40"
CWX |
Inquire |
950
|
950
|
Inquire |
450 -
650
|
325
|
|
45"
CWX |
Inquire |
1,800
|
1,800
|
Inquire |
570 -
1,100
|
650
|
|
45"
DCWX |
Inquire |
1,900
|
1,900
|
Inquire |
625
- 1,200
|
725
|
|
55"
CWX |
Inquire |
2,975
|
2,975
|
Inquire |
725
- 1,525
|
1,050
|
|
55"
DCWX |
Inquire |
3,200
|
3,200
|
Inquire |
775
- 1,650
|
1,125
|
|
66"
CWX |
Inquire |
4,800
|
4,800
|
Inquire |
2,500 -
3,100
|
1,600
|
|
66"
DCWX |
Inquire |
5,200
|
5,200
|
Inquire |
2,700 -
3,300
|
1,700
|
|
77"
DCWX |
Inquire |
6,790
|
6,790
|
Inquire |
4,370 |
2,200
|
|
83"
CWX |
Inquire |
8,330
|
8,330
|
Inquire |
5,370 |
2,720
|
|
83"
DCWX |
Inquire |
9,580
|
9,580
|
Inquire |
6,180 |
3,130
|
|
(Capacities
based on tests under optimum conditions;
actual performance will
vary with specific operating conditions.)
|
|
|
|
Technical
Specifications |
|
|
Cold
Current
(A)
@ 230 V |
Magnet
Power
(W) |
Magnet
Weight
(Lbs.) |
Minimum
Cable
Size |
Controller
Size |
|
|
34"
CWX |
22 |
5,000 |
1,500 |
#10 |
CDS |
|
|
40"
CWX |
29 |
6,600 |
2,000 |
#8 |
RD1W |
|
|
45"
CWX |
46 |
10,500 |
3,100 |
#8 |
RD1W |
|
|
45"
DCWX |
44 |
10,000 |
3,850 |
#8 |
RD1W |
|
|
55"
CWX |
52 |
15,500 |
5,200 |
#6 |
RD1W |
|
|
55"
DCWX |
68 |
15,700 |
5,700 |
#6 |
RD1W |
|
|
66"
CWX |
103 |
23,700 |
7,700 |
#4 |
RD2A |
|
|
66"
DCWX |
105 |
24,200 |
8,700 |
#4 |
RD2A |
|
|
77"
DCWX |
100 |
23,100 |
14,300 |
#4 |
RD1W |
|
|
83"
CWX |
129 |
29,800 |
16,000 |
#2 |
RD2A |
|
|
83"
DCWX |
181 |
41,600 |
17,900 |
#1/0 |
RD3A |
|
|
(For
proper Generator sizing, use cold volts and size equal to or
greater than required to ensure sufficient power.) |
Top
To
get a customized solution for your specific application, complete a Lifting
Magnet Design Form (Excel form), contact the factory, or talk with the
Ohio rep / dealer nearest you.
|