Lifting Magnets
Magnet
Selector Guide
Power
Equipment Guide
Frequently
Asked Questions
Scrap
Handling and Auxiliary
Vers-A-Lift
Pow-R-Lite
Loadstar
Series
Super
Loadstar Series
AWX
Series
CWX
Series
AWL
Series
Rectangular
Grapple
Steel
Mill Type
SR
Series
HD
Fabricated Rectangular
Cast-Case
Rectangular
Bi-Polar
Coil
Handling (CL Type)
Accessories
Magnet
Controllers
DC
Power Supplies
Duty-Cycle
Generators
Safety
Disconnect Switch
Emergency
Power Supplies
Repairs
|
Home
/ Ohio / CWX
CWX
/ DWCX
The
CWX and DCWX series of copper wound lifting magnets provide maximum lift
in severe-duty, tough scrap handling applications. These copper wound
magnets feature either standard field or deep field designs to meet the
ever-growing demands for cost-effective, productive, long-lived
solutions.
Brochure
Page: CWX (Adobe
Acrobat File)
Typical
Applications

Lifting
Magnet Design Form (Excel form)
Features
-
Copper wound severe-duty magnets for
the toughest scrap handling applications
-
Added lifting capacity from copper
wound field
-
Ideal
for cable or hydraulic machines
-
Optional deep field design
(DCWX)
to provide an even more powerful gripping force
-
230 VDC standard; special voltages
available by request
|
Average
Lifting Capacity in Lbs.
(based on specifications from Institute of Scrap
Iron & Steel) |
|
Size
(dia.) |
#1
H.M.
|
#2
H.M. |
Steel
Turnings |
|
34"
CWX |
750
|
300 -
500
|
325
|
|
40"
CWX |
950
|
450 -
650
|
350
|
|
|
|
|
|
|
45"
DCWX |
1,900
|
625
- 1,200
|
725
|
|
55"
DCWX |
3,200
|
1,900
- 2,300
|
1,125
|
|
66"
DCWX |
5,200
|
2,700 -
3,300
|
1,700
|
|
71" DCWX |
6,015
|
3,850 - 4,400 |
1,925
|
|
77"
DCWX |
6,790
|
4,100
- 5,100 |
2,200
|
|
83"
DCWX |
9,580
|
5,650
- 7,300 |
3,130
|
|
93" DCWX |
11,950
|
7,000 - 9,000 |
3,700
|
|
(Capacities
based on tests under optimum conditions;
actual performance will
vary with specific operating conditions.)
|
|
|
|
Technical
Specifications |
|
|
Cold
Current
(A)
@ 230 V |
Required
Power
(kW) |
Magnet
Shipping
Weight
(Lbs.) |
Minimum
Cable
Size |
Controller
Size |
|
34"
CWX |
20 |
4.6 |
1,450 |
#10 |
CDS |
|
40"
CWX |
29 |
6.7 |
2,250 |
#8 |
RD-1W
/ MC-1A |
|
|
|
|
|
|
|
|
45"
DCWX |
42 |
9.7 |
4,425 |
#8 |
RD-1W
/ MC-1A |
|
55"
DCWX |
50 |
11.5 |
5,200 |
#6 |
RD-1W
/ MC-1A |
|
66"
DCWX |
78 |
17.9 |
8,750 |
#4 |
RD-1W
/ MC-1A |
|
71" DCWX |
92 |
21.2 |
11,150 |
#4 |
MC-1.5A |
|
77"
DCWX |
100 |
23 |
12,700 |
#2 |
MC-1.5A |
|
83"
DCWX |
181 |
41.6 |
17,250 |
#2 |
RD-3A |
|
93" DCWX |
188 |
43.2 |
20,100 |
#2 |
RD-3A |
|
(For
proper Generator sizing, use cold volts and size equal to or
greater than required to ensure sufficient power.) |
Top
To
get a customized solution for your specific application, complete a Lifting
Magnet Design Form (Excel form), contact the factory, or talk with the
Ohio rep / dealer nearest you.
|